Daily Maintenance and Repair of Industrial Dust Collector
Date:2016-08-16 Source:zk corp Views:
Industrial dust collector is an auxiliary equipment commonly used in the mining equipment and it is often used in cement, building materials, metallurgy, chemical industry, coal, electricity, refractory and non ore industry extension for dust control and material recycle. Industrial dust collector can maintain an efficient, daily maintenance is essential, there are twelve points we should take attention.
1 In the operation of the equipment, should be managed by designated personnel, and make a record run.
2 Management personnel should be familiar with the principle, performance and use of the dust catcher, and master the methods of adjustment and maintenance.
3 Speed reducer, ash conveying device and other mechanical moving parts should oil and change oil in accordance with the provisions, abnormal phenomenon should be eliminated in a timely manner.
4 Electromagnetic pulse valve failure, rule out in time, the internal impurities, moisture should be promptly cleaned, if the diaphragm damage it should be replaced in a timely manner.
5 when using timing type ash cleaning controller, we should periodically determine whether the cycle of the ash is normal, otherwise it should be adjusted in time. When constant pressure cleaning controller is used, the pressure switch should be periodically checked, whether the pressure port is jammed, and clean it up.
6 Check the seal on the manhole, if damaged or aging, replace it in time.
7 Measure process parameters regularly, such as volume, temperature and concentration, once abnormal is found, we should find the cause and treat timely.
8 Check the gas system regularly, ash handling system, if abnormal, remove it in a timely manner.
9 When device is powered, we should first connect the compressed air to the air storage tank, connect to the power controller, start the ash discharging device, if there are other devices in the system, we should start the downstream equipment.
10 When stop, the dust and exhaust fan should work for a period of time in order to remove moisture and dust within the device after stopping the process system. What we must pay attention to is that when the dust collector stops working, the dust collector must be repeatedly cleaned.
11 When stop, do not cut off the compressed air supply, especially in the wind turbine work, you must provide compressed air to the valve cylinder to ensure that the valve is in the open state.
12 If dust collector is in the normal work, ash device can't stop working, otherwise, ash in the hopper fill into the bag room, which forces dust collector to stop working.
Hope that the above method can help you, if there is any problem in the process of using the industrial dust collector, you can contact us in time.