Precautions for operating the pulse dust collector
Date:2017-05-10 Source:zk corp Views:
The temperature of the inlet gas of the dust collector should be strictly controlled to ensure that it is 25 degrees above the dew point and less than 70 degrees above the dew point. If the temperature is below the dew point, it will cause condensation, not only arouse fouling, but also clog the filter bag, so that the dust is difficult to clean and affect the normal operation of the dust collector. If the dust is too high, the dust is too high to ignite the dust. According to the requirements of operation and maintenance of pulse bag filter is to improve the performance and life expectancy of dust an important way, when the staff in the operation of dust collector, should pay attention to the following aspects:
1. Before use must first check the dust fan, motor, dust bag, controller, solenoid valve is intact, all aspects are confirmed before they can operate.
2. When the start of the pulse bag dust collector before the main equipment, the first dust collector to open 2-3min, stop is the reverse.
3. In accordance with the first fan, cleaning motor, high pressure air, the controller for the order to start the pulse bag filter, stop is the reverse order of the opposite.
4. The operation of the dust collector, must ensure that the main equipment is tight and intact.
5.For the oil and water separator and dust inside the bag of oil, water and other impurities to exclude the provisions of regular weekly twice.
6. The replacement of the dust bag is every two years, and at any time to check the dust bag wear and tear, and found a timely replacement of damage.
7. If have the level dust pipe, the annual opening of the cleaning hole, clean up the pipeline once a fouling. When the pulse bag filter for a long time to stop the operation, in addition to the need to thoroughly clean, the system before cooling, completely empty the bag room containing moisture, all put dry air. During the outage period, it is necessary to remove the ash from the hopper, clean the body and the drive part to be full of oil; pay attention to the fan cleaning, rust and other work to prevent dust and rain into the bearing (pay attention to the motor moisture) ; During the outage, to a regular short-term operation (air running), to ensure the normal operation of the dust removal system; completely emptying the cooling system cooling water to prevent cooling water accident.
After the usage of ZK CORP production pulse dust collector, 99.99% of the dust is collected down, the production site for governance, can be fully realized dust cleaner production, to environmental emissions standards, to prevent the occurrence of occupational diseases.